Four checks in every 4X panel.
4X Essential is our standard for identity, purity, net content, and rapid microbial DNA. Testing is performed within Helix's laboratory network under Helix's methods. Every result is reviewed and released by Helix. Full USP <71> sterility is an add-on that needs extra vials and at least 14 days of incubation. Below: what each check answers and its method status.
What we recommend, and why
4X Essential
$195The standard every compound should actually meet.
4X covers identity, purity, net content and a rapid microbial DNA screen at Layer 4. Full USP <71> sterility is an add-on.
8X Comprehensive
$595Extra depth for peace of mind - not because you need it.
8X adds endotoxin, heavy metals, post-reconstitution stability, and a fentanyl/analog adulterant screen. Worth it when you want maximum assurance or are vetting a brand-new source - but we will not pretend a clean 4X result is somehow incomplete.
Most labs upsell a higher “X” as if more layers automatically means a safer vial. That is a marketing gimmick. Both panels cover identity, purity, net content and rapid DNA; USP <71> is a separate add-on.
The three base determinations
Institutional Analytical StandardEach answers one specific question. Expected values, ranges, units and sources are locked and shown at result entry.
Identity
LC-MS/MS (ESI+)LC-MS/MS confirms exact monoisotopic mass and fragmentation identity, ±1 Da. Identity consistent with expected mass.
Purity
RP-HPLC 214nm (USP 621)RP-HPLC at 214nm isolates the main peak from related substances at the peptide-bond absorbance wavelength.
Net Peptide Content
Quantitative HPLC vs reference stdQuantitative HPLC against a qualified reference standard, stripping moisture, salts, and counter-ions like TFA. Reported as mg per vial.
Rapid DNA is the required fourth 4X layer and is a research target-DNA screen, not viable CFU enumeration, USP <61>, or USP <71>. It is executed as an independent analytical method under an approved protocol. USP <71> remains a separately selected two-media culture service with no less than 14 days of incubation and its own material, suitability, media-control, execution, and release evidence.
Sterility (Rapid PCR)
Qualification-bound DNA molecular research screenLayer 4 (Sterility) is a rapid PCR screen for microbial DNA. It is not a USP <71> sterility test or a USP <61> count. Full USP <71> sterility testing is available as an add-on.
The four expanded checks
Added by 8X ComprehensiveBelt-and-suspenders depth: endotoxin, heavy metals, post-reconstitution stability, and a fentanyl/analog adulterant screen. Worth it for maximum assurance or a brand-new source, not because a clean 4X result is incomplete.
Endotoxin
Kinetic chromogenic LALKinetic chromogenic LAL (USP 85). Reported in EU/mL and EU/mg against a stated limit.
Heavy Metals
ICP-MS (USP 232/233)ICP-MS (USP 232/233) for Pb, As, Cd, Hg at sub-ppb. Each element: result, unit, LOQ, and specification source.
Stability
Forced-degradation stabilityPost-reconstitution pH, clarity, and 24h forced-degradation kinetics on the submitted analytical article. Cross-vial consistency is a separate optional service, not part of Layer 7.
Fentanyl Screen
LC-MS/MS targeted adulterant screenLC-MS/MS targeted screen for fentanyl and common analogs (acetylfentanyl, carfentanil, and others). A harm-reduction adulterant check reported as detected / not-detected against a method detection limit.
Methods & validation status
Each row is one of the eight layers above. Method status shows how a result may be described on a released certificate. Expected criteria and sources are locked and shown, and results are recorded against them.
Validated for the stated analyte, matrix, and range.
An established compendial procedure (e.g. USP) verified as suitable for use.
A research-screen or qualification-held method, reported within its stated limits.
| Layer · Method | Reference | Instrument | Status | Range | LOQ |
|---|---|---|---|---|---|
| 01Identity | Intact mass + MS/MS · qualification target | LC-MS/MS (tandem quadrupole); LC/MS (single quadrupole) | Research / qualification-held | PROPOSED · ±1 Da | Not qualified |
| 02Purity | USP <621> framework · exact method pending | RP-HPLC with diode-array detection | Research / qualification-held | Not qualified | Not qualified |
| 03Net Peptide Content | Quantitative HPLC vs reference standard · qualification target | RP-HPLC with diode-array detection | Research / qualification-held | Not qualified | Not qualified |
| 04Sterility (Rapid PCR) | Qualification-bound molecular target screen (not USP 61 or USP 71) | Candidate evidence under qualification | Research / qualification-held | NOT CONFIGURED · STAFF RESOLUTION | Matrix-specific signed threshold required |
| 05Endotoxin | USP <85> framework · exact matrix suitability pending | Controlled equipment binding not configured | Research / qualification-held | Not qualified | Not qualified |
| 06Heavy Metals | USP <232>/<233> framework · exact method pending | ICP-MS (triple quadrupole) | Research / qualification-held | Not qualified | Not qualified |
| 07Stability | Post-reconstitution kinetics · research target | Controlled equipment binding not configured | Research / qualification-held | Not qualified | Not qualified |
| 08Fentanyl Screen | Targeted LC-MS/MS adulterant screen · research target | Controlled equipment binding not configured | Research / qualification-held | Not qualified | Not qualified |
Helix Analytics does not hold ISO/IEC 17025 accreditation. Testing is performed within Helix's laboratory network under Helix's methods. Every result is reviewed and released by Helix. Helix does not disclose which laboratory performed a given analysis. Each result shows its method status beside it.
What we test, and what we do not
Our catalog accepts peptides, exact oral tablets and capsules, and declared aqueous, oil, or other supported presentations. Product-specific methods and criteria still govern release. Schedule III requests may be saved, but do not ship until the submitting account's authorization is verified.
ACCEPTED
| Category | Examples | Accepted form |
|---|---|---|
| Peptides | BPC-157, semaglutide, tirzepatide, CJC-1295, ipamorelin, TB-500, KPV, and blends of them | Lyophilized powder, aqueous solution, cartridge |
| Peptide blends | Any combination of the peptides above A blend is certified per component. An area percent across a blend is not a purity figure for any one of them. | Lyophilized powder, aqueous solution |
| Peptide hydrolysates | Cerebrolysin, cerebroprotein hydrolysate These are defined mixtures, not single molecules, so the certificate carries a molecular-weight distribution and a composition profile instead of an accurate mass and a purity percent. Tell us which preparation you sent: Cerebrolysin and the generic cerebroprotein hydrolysates have different peptide profiles, and a result from one says nothing about the other. | Lyophilized powder, aqueous solution |
| Amino acids | L-arginine, L-citrulline, L-methionine, L-ornithine These respond weakly at our purity wavelength, so quantitation is by mass rather than by area percent. | Lyophilized powder, aqueous solution |
| Small molecules with a real chromophore | 5-Amino-1MQ, AICAR, SLU-PP-332, thiamine, pyridoxine, methylene blue | Lyophilized powder, aqueous or oil solution, capsule, tablet |
| Catalog oral products | Exact supplier-listed tablets and capsules, including catalog SARMs and ancillary small molecules Intake is conditional on the exact SKU. PASS requires product-specific reference material, method fit, source-backed criteria, and the submitted strength. A peptide panel is never substituted for an oral small-molecule method. | Tablet, capsule |
| Oil and other non-aqueous preparations | Exact catalog injection presentations whose vehicle is declared as oil or another non-aqueous carrier Vehicle identity is not inferred from a supplier section heading. Schedule III articles separately require verified customer authorization before shipping or custody. | Solution or suspension; vehicle recorded separately as oil, aqueous, mixed, or unknown |
| Vitamins and cofactors | Methylcobalamin and cyanocobalamin (B12), NAD+ B12 is photolabile, and the cyano and methyl forms are distinct molecules. Tell us which one you sent. | Lyophilized powder, aqueous solution |
| Polar small molecules | L-carnitine, choline chloride, myo-inositol These are invisible to a reverse-phase purity method and are quantified on a separate lane. | Lyophilized powder, aqueous solution |
| Copper peptide complexes | GHK-Cu, AHK-Cu The copper is not held by a covalent bond and our standard purity lane strips it. These are quantified on a method that leaves the complex intact, and the copper content is reported separately. | Lyophilized powder, aqueous solution |
CONDITIONAL INTAKE
These are not judgements about the products. Declined categories lack a defensible current testing route; conditional categories remain selectable while their exact authorization, presentation, method, or criteria are resolved.
Schedule III testing is conditionally available. You may select and save the exact product now, but Helix will not release a shipping address, accept custody, or begin work until the submitting company or account has a current verified authorization for the registered location and schedule.
Catalog tablets, capsules, and related small molecules may enter conditional testing. PASS requires the exact analyte, presentation, matched reference standard, method, and face-up acceptance criteria. A peptide method is never substituted for a small-molecule method.
Oil vehicles are supported as a separate controlled presentation. Declare the vehicle exactly. PASS requires oil-specific preparation, method suitability, reference material, and acceptance criteria.
Exact products already present in the controlled catalog may enter conditional testing. Unlisted finished drug products require a method-and-authority preflight; no peptide panel, generic product family, or customer label substitutes for product-specific criteria.
You may select and save an exact Schedule III catalog product. Helix does not release shipping instructions, accept custody, or begin analysis until the submitting company or account has a current verified authorization for the registered location and Schedule III activity. The credential and its evidence remain private; the order stores only a masked verification snapshot.
NOT ACCEPTED
Cannabinoid potency is a different method on a different matrix, and it is separately regulated at state level. We do not offer it.
An extract has no single molecular identity, so there is no accurate mass to confirm and an area percent would not mean what it appears to mean.
Accreditation status, stated plainly
No decorative badges, no claims beyond the evidence. Here is the quality system behind every result, and exactly where we stand on accreditation.
Controlled QMS evidence
Reopenable SOP, chain-of-custody, equipment-qualification, and retest-policy artifacts support conformance.
Method Qualification
Before activation, the signed record must state analyte, matrix, range, specificity, precision, accuracy, quantitation limit, controls, approval, and revision.
Reference Standards
Qualified reference-material lots, recorded blanks, controls, and suitability checks remain face up.
Review and release
Every certificate is reviewed and released by Helix before it is signed.
Correction Policy
Amendments create a new version; prior versions are superseded but retained. Full revision history is public on verify.
Zero Conflicts
Helix owns no retail brands and holds no inventory.
Institutional Verification & Standards
Helix Analytics conducts testing strictly under pre-approved institutional agreements and publishes signed Certificates of Analysis for independent cryptographic verification.